NA-2018-CSO-01, Approval of Delegations of Nuclear Safety Authorities
Document text
Text extracted from the attached file. Refer to the original document for the authoritative version.
Section 1
Department of Energy
National Nuclear Security Administration
Washington, DC 20585
May 21, 2018
MEMORANDUM FOR PETER D. RODRIK
LIVERMORE FIELD OFFICE
THRU: JAMES J. MCCONNELL
CENTRAL TECHNICAL AUTHORITY
FROM: PATRICK T. CAHALANE
COGNIZANT SECRETARIAL OFFICER FOR SAFETY
SUBJECT: Approval of Delegations of Nuclear Safety Authorities
REFERENCES: (1) Memorandum from Peter D. Rodrik to Patrick Cahalane,
“Request for National Nuclear Security Administration Nuclear
Safety Delegations for the Livermore Field Office,”
March 16, 2018
(2) Memorandum from James J. McConnell to Nicole Nelson-
Jean, “Approval of Nuclear Safety Delegations for Livermore
Field Office,” July 28, 2014
(3) NNSA Business Operating Procedure 07.01, Delegations of
Nuclear Safety Authority, October 28, 2014
By Reference (1), you requested delegations of nuclear safety authorities for yourself and
Mr. Douglas Eddy, Senior Technical Safety Advisor (STSA). Your requested delegated
authorities are to update and reaffirm the authorities, originally granted in Reference (2),
due to your appointment as the Livermore Field Office (LFO) Manager. The requested
delegated authorities for Mr. Eddy are to enable him to act in your absence from the
office on urgent nuclear safety matters. You also informed me that the delegated nuclear
safety authorities to Mr. Samuel D. Brinker are no longer necessary due to his transfer to
a non-safety related position.
I approve the delegations to yourself and Mr. Eddy. I also rescind the delegated
authorities for Mr. Brinker.
Although your delegated authorities as specified in Reference (2) remain valid, I consider
it prudent to confirm that the bases upon which the delegations were made have not
diminished in the period of time since Reference (2) was issued. Therefore, your
qualifications and updated experience were re-evaluated and documented per
2
Reference (3). This evaluation determined that you continue to satisfy the requirements
for delegation of your nuclear safety authorities.
Mr. Eddy qualified as Senior Technical Safety Manager (STSM) in December 2017. He
is due for STSM requalification in April 2022. He completed Nuclear Executive
Leadership Training in 2017. His experience at LFO is noteworthy. Prior to serving in
his present position, Mr. Eddy served for 15 months as Acting STSA/Safety Basis and
Engineering Lead, four years as Nuclear Facility Operations Team Leader, nine years as
Operations Manager at the National Ignition Facility, and previously for seven years as
Senior Facility Representative for Nuclear Facilities.
The capabilities, capacities, and framework to perform these delegations were evaluated
in the 2016 Biennial Review of LFO. This review resulted in evaluation of Criticality
Safety as “Exceeds Expectations” and all other applicable areas as “Meets Expectations.”
The review determined that LFO had policies and procedures in effect and sufficient
technical staff and resources that would support LFO’s proper execution of these
delegated authorities.
I delegate the following nuclear safety authorities to you and Mr. Douglas Eddy:
Safety Design Basis - Approval Authority for safety design basis
documents for Hazard Category 2 and 3 nuclear facilities developed in
accordance with DOE-STD-1189-2016. This approval authority covers
safety design basis documents prepared in accordance with DOE-STD-
1189-2008 in cases where a project is following that standard.
Section 2
Safety Basis - Approval Authority for safety basis documents for Hazard
Category 2 and 3 nuclear facilities are required by 10 CFR 830
Subpart B, Safety Basis Requirements. This includes Documented Safety
Analyses, Technical Safety Requirements, Unreviewed Safety Question
(USQ) procedures, documents that result from positive USQ
determinations, and revisions to those documents.
Startup and Restart - Authorization Authority for startup of Hazard
Category 3 nuclear facilities and for restart of Hazard Category 2 and 3
nuclear facilities.
These delegations remain valid while you and Mr. Eddy serve in your current positions
and maintain STSM qualification.
Consistent with Section 3.2 of DOE-STD-1104-2016, Review and Approval of Nuclear
Facility Safety basis and Safety Design Basis Documents, the safety basis delegation
excludes approval authority for proposed changes to an existing facility safety basis
where no viable control strategy exists to prevent or mitigate the offsite dose
consequence of an accident scenario from exceeding the Evaluation Guideline.
The Central Technical Authority concurs with the delegation of nuclear safety authorities
to Mr. Eddy.
3
cc:
J. McConnell, NA-50
D. Sigg, NA-51
J. Roberson, NA-51
P. Rhoads, NA-50
D. Schwendenman, NA-512
S. Johnson, NA-512
D. Eddy, LFO
-·· .. ~~l/1/1V•~;'i:JIIt'4--_.,.",.- Department of Energy
National Nuclear Security Administration
Livermore Field Office
PO Box 808, L-293
7000 EastAvenue
Livermore, California 94551-0808
MAR 16 2018
5481.1.3.5
COR-AMO-2/28/20 18-782614
MEMORANDUM FOR PATRICK T. CAHALANE
PRlNCfP AL DEPUTY ASSOCIATE ADMINISTRATOR
FOR SAFETY, INFRASTRUCTURE, AND OPERATIONS
FROM: PETER D. RODRIK /-) ") Il ~
MANAGER ,~ I/. "&A%~
SUBJECT: Request for National Nuclear Security Administration Nuclear Safety
Delegations for the Livermore Field Office
REFERENCE: Business Operating Procedure-07.01 (J. McConnell), Delegations oj
Nuclear Safety Authority, dated October 28, 2014
Per the delegation procedure in the Reference, attached is my request for delegation of Nuclear
Safety Authorities to be re-affirmed due to my appointment as the Livermore Field Office (LFO)
Manager. I also request safety authorities be delegated to Mr. Douglas Eddy, LFO Senior
Technical Safety Advisor, in the event that I am out of the office and unavailable to act on urgent
nuclear safety matters. Completed Delegation Nomination Forms for myself and
Mr. Eddy are attached.
This memorandum also serves as notification that the delegated approval authority for
Mr. Samuel D. Brinker is rescinded due to a change to a different non-safety related position.
Should you have any questions, please contact me at (925) 422-6265.
Attachments:
(1) Peter D. Rodrik, LFO National Nuclear Security Administration (NNSA) Delegation
Nomination Form
(2) Douglas Eddy, LFO NNSA Delegation Nomination Form
cc (wiatt.):
J. McConnell, NA-50
D. Sigg, NA-51
D. Bullen, DNFSB
Livermore Field Office
National Nuclear Security Administration Delegation Nomination Form
Delegate Name:
Peter D. Rodrik
Delegate’s Organization / Position:
Livermore Field Office (LFO)/ Manager
Delegations Proposed:
Safety Design Basis: Approval authority for safety design basis documents developed in
accordance with Department of Energy (DOE)-Standard (STD)-1189-2016, Integration of Safety
into the Design Process, for Hazard Category 2 and 3 nuclear facilities. This approval authority
covers safety design basis documents prepared in accordance with DOE-STD-1189-2008 in
cases where a project is following the previous version of the standard.
Section 3
Safety Basis: Approval authority for safety basis documents for Hazard Category 2 and 3
nuclear facilities required by 10 Code of Federal Regulations (CFR) 830 Subpart B. This
includes documented safety analyses, technical safety requirements, Unreviewed Safety
Question (USQ) procedures, documents that result from positive USQ determinations, and
revisions to these documents.
Startup: Authorization authority for startup of Hazard Category 3 nuclear facilities and restart of
Hazard Category 2 and 3 nuclear facilities.
Delegate’s Education and Experience:
• Bachelor of Science in Chemical Engineering (1985), University of Iowa, Iowa City, IA
• Biology, Earth Science, Environmental Management/Law, RCRA Post-Graduate Work
(1993-1995), University of Denver, Denver, CO
• 33 years of Contractor/Federal experience including:
o Two months as the Manager, LFO, 1/2018 - Present
o 5 months as the Acting Manager, LFO, 8/2017 - 1/2018
o Two years as the Deputy Manager, LFO, 10/2015 - 8/2017
o Nine years as the Senior Technical Safety Advisor (STSA), LFO, 9/2007 - 10/2015
o Seven years as Senior Nuclear Safety Enforcement Specialist, Office of Price Anderson
Enforcement, 2/2001 - 9/2007
o Two years as Team Leader for Safeguards, Office of Safeguards and Security
Evaluations, 3/1999 - 2/2001
o Seven years as Nuclear Engineer, Office of Environment, Safety, and Health Residents,
Rocky Flats Site, 9/1992 -3/1999
o Two years as a Resident Inspector, Nuclear Regulatory Commission, 3/1990 - 9/1992
o Five years as Chief/Shift Refueling Engineer, Mare Island Shipyard, 7/1985 - 3/1990
Delegate’s Qualification:
• Senior Technical Safety Manager, 4/2014; re-qualification due 4/2019
• Nuclear Executive Leadership Training, 2009
• National Academy for Nuclear Training, Senior Nuclear Plant Management Course
(INPO), 2010
• Federal Executive Institute Leadership for a Democratic Society, 2006
Compensatory Measures:
No Compensatory Measures are needed.
Organization’s Capabilities / Capacities:
Adequate site capabilities and capacities exist and were evidenced in the National Nuclear
Security Administration (NNSA) biennial review of the LFO conducted in May 2016. The
following are the results from the review:
Functional Area Grade Comments
Safety Basis Meets Expectations Demonstrates site’s
capability/capacity for
implementation of safety basis
requirements per 10 CFR 830
Subpart B.
Startup/Restart Meets Expectations Demonstrates site’s
capability/capacity for effective
processes to achieve and verify
readiness.
Criticality Safety Exceeds Expectations Demonstrates site’s
capability/capacity of an
exceptional level of oversight
performance in the criticality
safety program.
Quality Assurance (QA) Meets Expectations Demonstrates site’s
capability/capacity for delegation
to approve QA program.
Other Conditions to Justify Delegation:
Mr. Peter D. Rodrik was granted approval authority as the LFO STSA in July 2014. In the
delegation memo, it stated, “These delegations remain valid while Mr. Rodrik maintains STSM
qualifications.” This NNSA Delegation Nomination Form re-affirmation request is to ensure
that the delegation records accurately reflect Mr. Rodrik’s change of position from the LFO
STSA to the LFO Manager.
Livermore Field Office
National Nuclear Security Administration Delegation Nomination Form
Delegate Name:
Mr. Douglas Eddy
Delegate’s Organization / Position:
Livermore Field Office (LFO) / Senior Technical Safety Advisor (STSA)
(LFO Manager’s Office)
Section 4
Delegations Proposed:
Safety Design Basis: Approval authority for safety design basis documents developed in
accordance with Department of Energy (DOE)-Standard (STD)-1189-2016, Integration of Safety
into the Design Process, for Hazard Category 2 and 3 nuclear facilities. This approval authority
covers safety design basis documents prepared in accordance with DOE-STD-1189-2008 in
cases where a project is following the previous version of the standard.
Safety Basis: Approval authority for safety basis documents for Hazard Category 2 and 3 nuclear
facilities required by 10 Code of Federal Regulations (CFR) 830 Subpart B. This includes
documented safety analyses, technical safety requirements, Unreviewed Safety Question (USQ)
procedures, documents that result from positive USQ determinations, and revisions to these
documents.
Startup: Authorization authority for startup of Hazard Category 3 nuclear facilities and restart of
Hazard Category 2 and 3 nuclear facilities.
Delegate’s Education and Experience:
• Bachelor of Science in Biology (concentration Molecular Biology) with a double major
Bachelor of Arts in Chemistry (concentration Biochemistry) (1989), San Jose State
University, San Jose, CA
• Laser Technology, Vacuum Technology, Engineering, & Occupational Safety Courses
(1999 - 2011), Las Positas Community College, Livermore, CA
• Graduate of D1G Nuclear Power Prototype, Knolls Atomic Power Laboratory, Ballston Spa,
NY (1980)
• Graduate of Naval Nuclear Power School, Orlando, FL (1979)
• 32 years of Contractor/Federal experience including:
o Nine months as the STSA, LFO, 3/2017 - Present
o 15 months as Acting STSA/Safety Basis and Engineering Lead, LFO, 12/2015 - 3/2017
o Four years as Nuclear Facility Operations Team Leader, LFO, 6/2011 - 12/2015
o Nine years as Operations Manager, National Nuclear Security Administration (NNSA)
Office of the National Ignition Facility, Livermore, CA 3/2002 - 6/2011
o Three years as Operations Team Leader/Inertial Confinement Fusion Program Manager,
LFO, 6/1999 - 3/2002
o Seven years Senior Facility Representative for Nuclear Facilities, Livermore Site Office,
4/1992 - 6/1999
o Two years Health Physicist, Lockheed Missiles and Space, Sunnyvale, CA
2/1990 - 4/1992
o Eight months as a Scientific Associate, Kirk Mayer Inc., subcontractor to Lawrence
Livermore National Laboratory, Livermore, CA 4/1989 - 2/1990
o Six months as an Analytical Chemist, NWT Corporation, San Jose CA 8/1988 - 4/1989
o Four years Nuclear Electrical Operator/Shutdown Reactor Operator, US Naval Nuclear
Power Program, USS South Carolina CGN-37 6/1980 – 6/1984
Delegate’s Qualification:
• Senior Technical Safety Manager, 12/2017
• Nuclear Executive Leadership Training, 8/2017
Compensatory Measures:
No Compensatory Measures are needed.
Organization’s Capabilities / Capacities:
Adequate site capabilities and capacities exist and were evidenced in the NNSA biennial review
of LFO conducted in May 2016. The following are the results from the review:
Functional Area Grade Comments
Safety Basis Meets Expectations Demonstrates site’s
capability/capacity for
implementation of safety
basis requirements per 10
CFR 830 Subpart B.
Startup/Restart Meets Expectations Demonstrates site’s
capability/capacity for
effective processes to achieve
and verify readiness.
Criticality Safety Exceeds Expectations Demonstrates site’s
capability/capacity of an
exceptional level of oversight
performance in the criticality
safety program.
Quality Assurance (QA) Meets Expectations Demonstrates site’s
capability/capacity for
delegation to approve QA
program.
Section 5
Other Conditions to Justify Delegation:
The LFO STSA position is a part of the LFO Manager’s Office and directly supports and reports
to the LFO Manager.
This request also meets a May 2016 NNSA biennial review opportunity for improvement, which
recommended that LFO obtain approval authority for startup and restart for another qualified
Senior Technical Safety Manager as a backup, such as the STSA, to cover cases when the LFO
Manager is not available.
NA-51 Delegation Review
Douglas Eddy
Page 1 of 2
Delegated Authorities Requested
Criteria for Individuals and
Review Results
Site Criteria and Review Results Comments
1. Safety Design Basis
For new or major modifications to Hazard
Category 2 and 3 nuclear facilities,
approval authority for the following:
(1) Safety Design Strategies and
associated approval
documentation
(2) Conceptual Safety Design Reports,
Preliminary Safety Design
Reports, and associated safety
review letters
(3) Preliminary Documented Safety
Analyses and associated Safety
Evaluation Reports
2. Safety Basis
For new or existing Hazard Category 2
and 3 nuclear facilities, approval authority
for the following:
(1) Documented Safety Analyses
(2) Technical Safety Requirements
(3) Unreviewed Safety Question
procedures
(4) Justifications for Continued
Operation
(5) Evaluations of the Safety of the
Situation (as required)
BOP 07.01 Criteria:
(1) Senior Technical Safety
Manager (STSM) qualified.
(2) Successful completion of
Nuclear Executive Leadership
Training (NELT).
Review:
Mr. Eddy completed NELT in
August 2017 and qualified as
STSM in December 2017.
Mr. Eddy holds a Bachelor of
Science in Biology and a
Bachelor of Arts in Chemistry,
San Jose State University, San
Jose, CA.
Prior to serving in his current
position at Livermore Field
Office (LFO), Mr. Eddy served for
15 months as Acting Senior
Technical Safety Advisor/Safety
Basis and Engineering Lead, four
years as Nuclear Facility
Operations Team Leader, nine
years as Operations Manager at
NIF, and previously for seven
years as Senior Facility
Representative for Nuclear
Facilities.
BOP 07.01 Criteria:
(1) Delegations shall be made only
where the candidate’s organization
possesses or has access to
sufficient staff with the necessary
qualifications, experience, and
expertise to support the candidate
for the authorities being delegated.
(2) Delegations shall be made only
where the candidate’s organization
has the proper framework of
processes and procedures, as well
as adequate resources and funding,
to implement the delegated
authorities.
Review:
The 2016 BR of LFO was conducted
in September 2016 and included 11
Functional Areas, including Safety
Basis and Startup and Restart of
Nuclear Facilities. Objectives were
met in all areas. Additionally, a
positive trend in performance was
noted in multiple functional areas.
Mr. Eddy is the Senior
Technical Safety
Advisor for LFO and has
extensive experience
with nuclear safety at
the site.
Since Mr. Eddy is not
serving in a Manager or
Deputy Manager
position, CTA
concurrence for the
requested delegated
authorities is required.
LFO currently has a
non-technical Acting
Deputy Manager.
Delegating these
authorities to Mr. Eddy
provides backup
capability to exercise
the authorities when
the Manager is
unavailable.
NA-51 Delegation Review
Douglas Eddy
Page 2 of 2
3. Startup
Authorization Authority for startup of
Section 6
Hazard Category 3 nuclear facilities
and restart of Hazard Category 2
and 3 nuclear facilities.
Conclusion: Recommend approving the requested delegated authorities.
NA-50 Senior Manager Concurrence:
Jeffry Roberson
Senior Technical Advisor
Date Daniel Schwendenman
Director, Office of Nuclear Safety Services
Date
2018-05-07T11:03:31-0400
Jeffry L. Roberson
2018-05-07T11:05:17-0600
DANIEL SCHWENDENMAN
NA-51 Delegation Review
Peter D. Rodrik
Page 1 of 2
Delegated Authorities Requested
Criteria for Individuals and
Review Results
Site Criteria and Review Results Comments
1. Safety Design Basis
For new or major modifications to Hazard
Category 2 and 3 nuclear facilities,
approval authority for the following:
(1) Safety Design Strategies and
associated approval
documentation
(2) Conceptual Safety Design Reports,
Preliminary Safety Design
Reports, and associated safety
review letters
(3) Preliminary Documented Safety
Analyses and associated Safety
Evaluation Reports
2. Safety Basis
For new or existing Hazard Category 2
and 3 nuclear facilities, approval authority
for the following:
(1) Documented Safety Analyses
(2) Technical Safety Requirements
(3) Unreviewed Safety Question
procedures
(4) Justifications for Continued
Operation
(5) Evaluations of the Safety of the
Situation (as required)
BOP 07.01 Criteria:
(1) Senior Technical Safety
Manager (STSM) qualified.
(2) Successful completion of
Nuclear Executive Leadership
Training (NELT).
Review:
Mr. Rodrik completed NELT in
July 2009 and requalified as
STSM in 2014. He is due for
requalification in 2019.
Mr. Rodrik currently serves as
Manager of the Livermore Field
Office (LFO) and is currently
responsible for proper execution
of these delegated authorities.
This delegation updates his
authorities. He previously served
as Acting Manager, Deputy
Manager, and Senior Technical
Safety Advisor, LFO, where he
held these same authorities in
each position.
BOP 07.01 Criteria:
(1) Delegations shall be made only
where the candidate’s organization
possesses or has access to
sufficient staff with the necessary
qualifications, experience, and
expertise to support the candidate
for the authorities being delegated.
(2) Delegations shall be made only
where the candidate’s organization
has the proper framework of
processes and procedures, as well
as adequate resources and funding,
to implement the delegated
authorities.
Review:
The 2016 BR of LFO was conducted
in September 2016 and included 11
Functional Areas, including Safety
Basis and Startup and Restart of
Nuclear Facilities. Objectives were
met in all areas. Additionally, a
positive trend in performance was
noted in multiple functional areas.
Mr. Rodrik is the
Manager of LFO, and
he and the site meet
the criteria for these
delegations of
authority.
CTA concurrence is not
required.
NA-51 Delegation Review
Peter D. Rodrik
Page 2 of 2
3. Startup
Authorization Authority for startup of
Hazard Category 3 nuclear facilities
and restart of Hazard Category 2
and 3 nuclear facilities.
Conclusion: Mr. Rodrik currently serves as Manager of the Livermore Field Office and exercises these authorities as previously delegated in
2014. This action updates his authorities due to his recent appointment as the Manager.
Recommend approving the requested delegated authorities.
NA-50 Senior Manager Concurrence:
Jeffry Roberson
Senior Technical Advisor
Date Daniel Schwendenman
Director, Office of Nuclear Safety Services
Date
2018-05-07T11:04:03-0400
Jeffry L. Roberson
2018-05-07T11:04:24-0600
DANIEL SCHWENDENMAN